35kV Cable Branching Cabinet

35kV Cable Branching Cabinet

The 35kV high-voltage cable branching cabinet for photovoltaic power generation is equipped with lightning arresters.

35kV cable branching cabinets are widely used in wind power plants and photovoltaic power generation projects. The cabinet can be equipped with isolating switches and lightning arresters. It connects power cables to box-type substations and ring main units, serving functions such as connection, tapping, branching, or switching, providing great convenience for cable network systems.

Description

Operating Conditions:

  • Ambient temperature: -30℃ to +40℃

  • Relative humidity: Daily average ≤95%, monthly average ≤90%

  • Maximum altitude: 3000 meters

Product Features (35kV with Isolating Switch):

  • Customizable options: Prefabricated plug-in connectors or cold/hot-shrink cable terminations.

  • Fully insulated, fully sealed, fully waterproof, maintenance-free, safe, and reliable.

Functional Characteristics:

  • Fully insulated, fully sealed, maintenance-free, ensuring personal safety.

  • Eco-friendly outdoor design with HV live display simplifies urban cable networks and reduces investment.

  • Outdoor type, dustproof, moisture-proof, flood-resistant, corrosion-resistant, highly adaptable, flexible configuration.

  • Compact size, aesthetically pleasing, simple installation, easy operational switching.

  • Can be equipped with voltage indicators, fault indicators, lightning arresters, etc.

  • Advanced domestic HV equipment, filling the gap for 40.5kV(35kV) switch-equipped branching cabinets.

  • Suitable for 35kV AC 50Hz/60Hz transmission/distribution lines; can be used in 35kV prefabricated substations.

  • Reduces cable runs and footprint, improves power supply reliability.

  • Can be equipped with GN27-40.5 isolating switches for circuit switching under voltage, no-load conditions.

Technical Parameters:

  1. Rated Voltage: 40.5kV

  2. Rated Operational Voltage: 35kV

  3. Rated Current: 630A

  4. Frequency: 50Hz

  5. Circuit Breaker Rated Breaking Current: 20kA

  6. Rated Short-Time Withstand Current: 20kA (Incoming & Main Bus) / 20kA (Outgoing)

  7. Rated Short-Time Current Duration: 3s

  8. Rated Peak Withstand Current: 50kA (Incoming & Main Bus) / 50kA (Outgoing)

  9. Circuit Breaker Rated Breaking Operations: 20 times

  10. Insulation Level:

    • 1min power-frequency withstand voltage: 42kV (ground) / 48kV (break)

    • Lightning impulse withstand voltage: 95kV (ground) / 110kV (break)

  11. Load Switch Breaking Capacity:

    • Normal load current: 630A

    • Earth fault current: 95A

    • No-load current: 30A

Mechanical Life:

  • Circuit Breaker: 10,000 operations

  • Load Switch: 2,000 operations

  • Manual operating mechanism

Operating Times:

  • Circuit Breaker Closing: 0.2s

  • Circuit Breaker Opening: 0.06s

  • Close-Open Time: 0.002s

  • Circuit Breaker Bounce Time: 0.002s

  • Clear open/close position indication required.

  • Main System Configuration: BIBI

  • Space and interfaces reserved for FTU unit.

Cabinet Structure & Features:

  1. Enclosure made of imported aluminum-zinc coated steel or cold-rolled steel.

  2. Reliable “five-prevention” interlock; HV live display.

  3. Protection rating ≥ IP3X.

  4. Wiring diagram on each cabinet door.

  5. Concealed lock on enclosure.

Key Features:

  1. Outdoor/indoor use, fully sealed, “five-prevention” safety, maintenance-free.

  2. Eco-friendly with HV display, simplifies networks, saves investment.

  3. Weather-resistant, flexible configuration for various wiring needs.

  4. Compact, aesthetically pleasing, easy installation/operation, flexible protection.

  5. Small footprint, low height, blends with environment, flexible wiring.

Operating Environment:

  • Location: Outdoor

  • Seismic Intensity: 8 degrees

  • Altitude: ≤1000m

  • Weather Conditions:

    • Ambient temperature: -10℃ to +45℃

    • Daily temperature variation: 30℃

    • Wind speed: 35m/s (10m height, 15-year return, 10-min avg)

    • Solar radiation: 0.1W/cm², 0.5m/s wind

    • Relative humidity: Daily avg 95%, monthly avg 90% (25℃)

    • Pollution level: Grade IV

    • Ice thickness: 0-30mm

System Conditions:

  • Rated Frequency: 50Hz

  • Nominal Voltage: 35kV

  • Operational Voltage: 40.5kV

  • Rated Power-Frequency Voltage (conductor to earth/screen): 26kV

Technical Requirements:

Basic Parameters:

Item Unit Technical Requirement
Rated Voltage kV 35
Rated Frequency Hz 50
Rated Current A 630
Rated Insulation Level kV 40.5
Rated Short-Duration Power-Frequency Withstand Voltage (rms) kV 117
Rated Lightning Impulse Withstand Voltage (peak) kV 200
Protection Level ≥ IP54
Cable Accessories
Impulse Withstand Voltage kV 200kV, ± polarity 10 times each, no breakdown/flashover
DC Withstand Voltage kV 104kV (negative polarity), 15min, no breakdown/flashover
Partial Discharge pC ≤10 @ 45kV

Design & Structure Requirements:

  • Function: For interconnecting cable lines and connecting to branch lines outdoors, enabling power distribution. Uses TMY copper busbars, composite insulation. Safe clearance ≥400mm.

  • Safety Design: Ensures safe operation, inspection, maintenance, voltage status indication, phasing, cable grounding, testing, and static discharge.

  • Enclosure:

    • Material: ≥3.0mm stainless steel or cold-rolled steel, robust for handling.

    • Coating: Electrostatic spray ≥150μm, uniform, adherent, color-fast for 15+ years.

    • Color: Coordinates with environment, clear warning signs.

    • Doors: Open >90°, with stops, seals, handles, concealed latches, rain/rust proof hinges, locks, external lock points.

    • Ventilation: Natural vents to reduce condensation.

    • Internal Insulation Barrier: With safety warnings.

    • Roof: Rain shield.

    • Diagram: Internal schematic with operating instructions.

    • Lifting: 4 lifting rings.

    • Waterproof: Protection rating ≥ IP54.

  • Earthing:

    • Complies with DL/T 621-1997. All exposed metal earthed.

    • Earthing conductor withstands rated short-time/peak current.

    • Dedicated earthing conductor with ≥2 visible connection points, clearly marked.

  • Insulation:

    • Composite insulation. Safe clearance ≥400mm.

    • Insulators: Flame-retardant, creepage distance >16mm/kV, support insulator creepage ≥648mm.

Inquiry Now